Gene Technology Center

New Sequencing System

  • HOME »
  • New Sequencing System

 

310 Usage Fees Details Fee Amount Important Reminder
Short capillary array 1 hour / sample
Up to 24 samples per use
300 yen / sample Each user must reserve using the Reservation Calendar
Long capillary array 3 hours / sample
Up to 8 samples per use
350 yen / sample Each user must reserve using the Reservation Calendar
3500 Usage Fees Details Fee Amount Important Reminder
Sequencing reaction and electrophoresis
Plasmid & PCR products
Sequencing reaction and purification
Big Dye Terminator Kit 3.1
Big Dye Xterminator Purification Kit
Electrophoresis
Output analysis results
1200 yen / sample Receiving your results may be delayed by several days depending on the circumstances or number of requests.
Ion Electrophoresis – Electrophoresis
– Output analysis results
2800 yen / Electrophoresis (run) – About 1 to 2 hours per run
– Up to 8 / run
– Please precipitate a 1.5 ml tube with ethanol and then dry it.
If you bring your own, shield it from light with aluminum foil

 

Usage Instructions

Analysis completed by researchers on their own: AB 310

  1. On the Reservation Calendar for the date you want to reserve the sequencer, fill in the start date, quantity, your department, your name, and extension number.
  2. Have samples prepared before your reservation time, then run them.
    In the Usage Record, fill in the necessary items.
  3. Once electrophoresis is completed, collect your samples and gather your data.
  4. In the Usage Record, fill in the usage end time.
  5. If you’ve printed anything, fill in how many pages were printed. Shut down the computer.

Sequence contracting: AB 3500

Sequence reaction and electrophoresis

What to bring

  1. Sequence Contract Request Form (Reaction and Electrophoresis) (fill out completely beforehand) Download

    Sequence Contract Request Form

  2. PCR product (100 ng) or Plasmid DNA (500 ng) to be a template
    Primers (when using ones not listed on the GTC primer list)
  3. CD-R or CD-RW for data storage
    (Fill in your department, your name, and extension number)

* Important Reminder

  • For analysis results, the read base sequence information and waveform raw data will be copied to CD and sent via university internal post
    (For those in a hurry, please mention this when making your request)
  • Samples will not be returned
  • Receiving your results may be delayed by several days depending on the circumstances or number of requests.

For electrophoresis only

What to bring

  1. Sequence Contract Request Form (Electrophoresis Only)
    Download Sequence Contract Request Form (Electrophoresis Only)
  2. Sample (ethanol precipitation state) shield with aluminum foil
  3. CD-R or CD-RW for data storage
    (Fill in your department, your name, and extension number)

* Important Reminder

  • For analysis results, the read base sequence information and waveform raw data will be copied to CD and sent via university internal post
    (For those in a hurry, please mention this when making your request)
  • Samples will not be returned
PAGETOP
Copyright © GTC All Rights Reserved.
Powered by WordPress & BizVektor Theme by Vektor,Inc. technology.